DIN Rail Controller with DALI® Drivers, 100-277V for Zum Lighting Control with Net and Link Communication
Model: ZUMNET-DIN-DLI
- Zum® wired DIN rail mounted DALI® drivers lighting controller
- Control of DALI compliant dimmable LED or fluorescent loads
- Integration with Zum modules, keypads, presence detectors, and daylight sensors (sold separately)
- Ethernet network connection to ZUM-HUB4 control system (sold separately)
- Integrated contact closure input
The Zum® wired DALI-2™ certified ZUMNET-DIN-DLI provides DALI® control for drivers and devices. The device can be wired to Zum devices for network expansion and to Zum Link devices for in-room control. Energy-saving options are available to enable daylighting, occupancy or vacancy sensing, and centralized monitoring and management. Room setup can be accomplished quickly through the Zum app.
DALI-2™ Certified and IEC 62386 Compliant
DALI® interface for systems that provides control of one DALI loop. Capable of controlling DT6 and DT8 DALI devices.
Zum Net Wired Technology
In a Zum network, Zum Net load controllers facilitate communications between rooms via Ethernet and can be daisy-chained for network expansion. Each device in the chain communicates to a Zum Hub control system for centralized monitoring, management, and reporting. Zum Link devices connect to Zum Net devices to provide in-room lighting control. Zum Link devices work together in a local ecosystem to provide customized solutions.
Zum Link Wired Technology
Zum Link technology enables in-room lighting control through keypads and sensors wired to controllers. Zum Wired devices connect via CBL-CAT5E-ZUMLINK-P CAT5e cable (sold separately) to RJ-45 ports to provide simple daisy-chaining and lighting control of compatible loads. The Zum Wired devices work together in a local ecosystem to provide customized solutions using the Zum app.
Energy Efficiency
Occupancy sensor, vacancy sensor, and daylight sensor connectivity enables significant energy savings. To reduce energy usage, lights turn off automatically when the room is vacant and dim gradually depending on the amount of natural daylight in the room.
DIN Rail Mounting
DIN rail Zum devices snap onto a standard DIN rail for installation in a wall mount enclosure (Crestron DIN-EN series or similar) or on a wall panel.
Override Contact Closure Input
An integrated contact closure provides the means to place all connected Zum Net and Zum Link devices into Emergency Override mode.
- Zum® wired DIN rail mounted DALI® drivers lighting controller
- Control of DALI compliant dimmable LED or fluorescent loads
- Integration with Zum modules, keypads, presence detectors, and daylight sensors (sold separately)
- Ethernet network connection to ZUM-HUB4 control system (sold separately)
- Integrated contact closure input
- DALI-2™ certified and IEC 62386 compliant
- 4M wide DIN rail mounting
- Warranty - Yes
- Spec Sheet available - Yes
- Load Control :
•DALI Load Types: Control of DALI compliant dimmable LED loads
•DALI Groups: 16
•DALI Drivers: 64
•DALI Bus Power Supply: Maximum: 0.23A; Guaranteed: 0.17A
•Line Voltage: 100-277VAC, 50/60 Hz
•Switch Rating: 16A 100-277VAC, 50/60 Hz; 1 HP at 120-277VAC
•Switch Lifetime: General Rating: 100,000 on/off operations, 16A at 277VAC; Motor Rating: 100,000 on/off operations, 1HP at 120/230/277VAC - Zum Link Power Bus Requirements:
•Max Current Consumption: 70mA With one DALI driver (2mA), without sensor terminal 190mA With 64 DALI drivers (128mA), without sensor terminal
•Max Allowable Sensor Terminal Current: 85mA Passthrough from Zum Link bus - Wired Communications:
•ZUMNET: (2) RJ-45 ports; Input for control system connection or Zum Net device; Output for Zum Net device daisy-chaining
•ZUMLINK: (2) RJ-45 ports; In-room Zum Link device daisy-chaining
•24V, OCC, GND: Occupancy sensor input; Spring clamp connector; Each terminal accepts one 20-24 AWG solid wire
•24V, PHO, GND: Photo sensor input; Spring clamp connector; Each terminal accepts one 20-24 AWG solid wire
•OVR, GND: Override control input; Spring clamp connector: Each terminal accepts one 20-24 AWG solid wire - Controls and Indicators:
•TEST: (1) Pushbutton and (1) green LED; Push to toggle the switched load output on and off; Press and hold to cycle the dimming level up and down; LED indicates that the load is turned on; LED lights and flashes during room setup and factory reset
•ZUMLINK Status: (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected
•ZUMNET Status: (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected Connections N, L, SW (Neutral, Line, Switch) (1) 3-pin terminal block; Each terminal accepts one 12-24 AWG wire DA-, DA+ (2) DALI input/output negative (DA-) and positive (DA+) Spring clamp connector Each terminal accepts one 14-24 AWG solid wire or 12-24 AWG stranded wire - Humidity: 10% to 90% RH (noncondensing)
- Heat Dissipation: 5 BTU/hr at 2mA DALI Loading, 0A passthrough; 7 BTU/hr at 128mA DALI Loading, 0A passthrough; 14 BTU/hr at 128mA DALI Loading, 16A passthrough
- Construction: Light gray polycarbonate housing with polycarbonate label overlay, 71 mm DIN rail mount, occupies 4M DIN module spaces, DIN 43380 for factor for enclosures with 45 mm front panel cutout
- Operating Temperature (Maximum): 131 F
- Operating Temperature (Minimum): 32 F
- Certifications: CE, FCC Part 15 Class B, IC, WEEE, IEC 62386, DALI-2 certified
- Depth: 2.32 in
- Height: 3.69 in
- Width: 2.79 in
- Product Weight: 0.29 lbs
- Color: White